Apc
APC AP8965 RACK PDU 2G. SWITCHED. ZEROU. AP8965
- UPC:
- 0000000000000
- MPN:
- AP8965
- Condition:
- New
- Availability:
- Available to Order: 3 - 4 weeks leadtime
Description
Network Management
Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage units from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.
Remote Individual Outlet Control
Remotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment).
Alarm Thresholds
Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems. (Note: Only available on units with the current monitoring capabilities. Please see SKU specifications for availability)
Local Current Monitoring Display
The aggregate current draw per power distribution unit is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip. (Available on designated SKUs only)
Power Delays
Allows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also allows users to predetermine which piece of equipment is turned on first so other equipment dependant on that unit will function properly.
Load indicator LED
Indicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits.
Flash Upgradeable
Quickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released. (Note: Networked units only)
Integrates with InfraStruXure Central
An IT-ready, scalable monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the network.
Design
PDU types
Switched
Product colour
Black
Rack capacity
0U
Features
Cable length
1.83 m
Certification
cUL,FCC Part 15 A,ICES-003,UL,VCCI A
RoHS compliance
Yes
Operational conditions
Non-operating altitude
0 - 15000 m
Operating altitude
0 - 3000 m
Operating relative humidity (H-H)
5 - 95 %
Operating temperature (T-T)
-5 - 45 �C
Storage relative humidity (H-H)
5 - 95 %
Storage temperature (T-T)
-25 - 65 �C
Package dimensions
Gross Weight (Package, kg)
10.32 kg
Packaging data
Package dimensions (WxDxH)
165 x 124 x 2040 mm
Ports & interfaces
AC outlets quantity
24 AC outlet(s)
Power plug
NEMA L21-20P
Power
AC input frequency
50 - 60 Hz
Maximum current
30 A
Nominal input voltage
208 V
Nominal output voltage
208 V
Product dimensions
Net Weight (Product, kg)
8.18 kg
Technical details
Sustainability certificates
RoHS
Vendor information
Brand Name
APC
Warranty
1 Year(s)
Weight & dimensions
Dimensions (WxDxH)
56 x 51 x 1829 mm
View AllClose
Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage units from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.
Remote Individual Outlet Control
Remotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment).
Alarm Thresholds
Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems. (Note: Only available on units with the current monitoring capabilities. Please see SKU specifications for availability)
Local Current Monitoring Display
The aggregate current draw per power distribution unit is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip. (Available on designated SKUs only)
Power Delays
Allows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also allows users to predetermine which piece of equipment is turned on first so other equipment dependant on that unit will function properly.
Load indicator LED
Indicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits.
Flash Upgradeable
Quickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released. (Note: Networked units only)
Integrates with InfraStruXure Central
An IT-ready, scalable monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the network.
Design
PDU types
Switched
Product colour
Black
Rack capacity
0U
Features
Cable length
1.83 m
Certification
cUL,FCC Part 15 A,ICES-003,UL,VCCI A
RoHS compliance
Yes
Operational conditions
Non-operating altitude
0 - 15000 m
Operating altitude
0 - 3000 m
Operating relative humidity (H-H)
5 - 95 %
Operating temperature (T-T)
-5 - 45 �C
Storage relative humidity (H-H)
5 - 95 %
Storage temperature (T-T)
-25 - 65 �C
Package dimensions
Gross Weight (Package, kg)
10.32 kg
Packaging data
Package dimensions (WxDxH)
165 x 124 x 2040 mm
Ports & interfaces
AC outlets quantity
24 AC outlet(s)
Power plug
NEMA L21-20P
Power
AC input frequency
50 - 60 Hz
Maximum current
30 A
Nominal input voltage
208 V
Nominal output voltage
208 V
Product dimensions
Net Weight (Product, kg)
8.18 kg
Technical details
Sustainability certificates
RoHS
Vendor information
Brand Name
APC
Warranty
1 Year(s)
Weight & dimensions
Dimensions (WxDxH)
56 x 51 x 1829 mm
Additional Information
Shipping: |
Available to Order - Call for ETA |
Delivery: |
Available to Order - Call for ETA |