Apc
APC SRV2KRI Uninterruptible Power Supply SRV2KRI
- UPC:
- 0000000000000
- MPN:
- SRV2KRI
- Condition:
- New
- Availability:
- Available to Order: 3 - 4 weeks leadtime
Description
Automatic internal bypass
Supplies utility power to the connected loads in the event of a UPS power overload or fault.
Automatic restart of loads after UPS shutdown
Automatically starts up the connected equipment upon the return of utility power.
ECO Mode
Operating mode that by-passes unused electrical components in good power conditions to achieve high operating efficiency without sacrificing protection.
Input power factor correction
Minimizes installation costs by enabling the use of smaller generators and cabling.
Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
LCD display
Alpha-Numeric Display which displays system parameters and alarms.
Serial connectivity
Provides management of the UPS via a serial port.
USB connectivity
Provides management of the UPS via a USB port (not available on all models).
Features
Management Software
Allows you to easily monitor your utility power and manage your UPS.
ECO Mode
Operating mode that by-passes unused electrical components in good power conditions to achieve high operating efficiency without sacrificing protection.
Input power factor correction
Minimizes installation costs by enabling the use of smaller generators and cabling.
High efficiency
High efficiency rates that remain stable even at lower operating power levels.
SmartSlot
Customize UPS capabilities with management cards.
Intuitive LCD interface
Provides clear and accurate information in multiple languages with the ability to configure the UPS locally with easy to use navigation keys.
Double conversion on-line topology
Guarantees a consistently high level of power quality. Any disturbances on the distribution waveform are regenerated via the zero transfer time AC to DC then DC to AC conversion process. The battery is only used as a back-up source.
Generator compatible
Ensures clean, uninterrupted power to protected equipment when generator power is used.
Wide input voltage range
Designed for harsh electrical environments to save battery life.
Serviceability
Disconnected battery notification
Warns when a battery is not available to provide backup power.
Audible alarms
Provides notification of changing utility power and UPS power conditions.
Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Predicitive failure notification
Provides early-warning fault analysis ensuring proactive component replacement.
Manageability
Serial connectivity
Provides management of the UPS via a serial port.
SmartSlot
Customize UPS capabilities with management cards.
LCD graphics display
Text and mimic diagrams that display modes of operation, system parameters and alarms.
Network manageable
Provides remote power management of the UPS over the network.
LED Indicators
Provide easy-to-read status of the unit and utility power conditions.
Availability
Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
Battery
Automatic battery test
Yes
Battery recharge time
4 Hour
Battery technology
Sealed Lead Acid (VRLA)
Design
Certification
CE, IEC 62040-1-1, IEC 62040-1-2 REACH
Display type
LCD
Form factor
Rackmount
LED indicators
Y, Yes
Product colour
Black
Rack capacity
2U
Features
Audible alarm modes
Alarm when on battery, Fault, Low battery alarm, Overload alarm
Audible alarm(s)
Yes
Auto-restart
Yes
Crest factor
3:1
ECO mode
Yes
Efficiency
88 %
Emergency Power Off (EPO)
No
Input frequency
40/70 Hz
Input operation voltage (max)
280 V
Input operation voltage (min)
160 V
Input power factor
0.95
Maintenance-free
Yes
Noise level
50 dB
Number of input phases
1
Number of output phases
1
Output frequency
50/60 Hz
Output operation voltage (max)
240 V
Output operation voltage (min)
220 V
Output power
1600 Watt
Output power capacity
2 kVA
Output power factor
0.8
Output voltage regulation
1 %
Output voltage Total Harmonic Distortion (THD)
3 %
Socket circuit breaker
Yes
Surge energy rating
600 J
UPS topology
Double-conversion (Online)
Waveform
Sine
Logistics data
Harmonized System (HS) code
85078000
Operational conditions
Operating altitude
0 - 3000 m
Operating relative humidity (H-H)
0 - 95 %
Operating temperature (T-T)
0 - 40 °C
Storage relative humidity (H-H)
0 - 95 %
Storage temperature (T-T)
-20 - 50 °C
Other features
Nominal input voltage
230 V
Nominal output voltage
230 V
Package dimensions
Depth (package,cm)
59.9 cm
Gross Weight (Package, kg)
23.66 kg
Height (package,cm)
14.2 cm
Width (package,cm)
55.1 cm
Packaging data
Cables included
USB cable
Manual
Yes
Software CD
Yes
Ports & interfaces
AC outlet types
C13 coupler
AC outlets quantity
4 AC outlet(s)
Serial interface
Yes
Serial ports quantity
1
SmartSlot
Yes
USB port
Yes
USB port type
USB Type-B
Product dimensions
Net Weight (Product, kg)
18.2 kg
Product Depth
46.2 cm
Product Height
8.6 cm
Product Width
43.7 cm
Technical details
Sustainability certificates
RoHS
Vendor information
Brand Name
APC
Warranty
1 Year(s)
View AllClose
Supplies utility power to the connected loads in the event of a UPS power overload or fault.
Automatic restart of loads after UPS shutdown
Automatically starts up the connected equipment upon the return of utility power.
ECO Mode
Operating mode that by-passes unused electrical components in good power conditions to achieve high operating efficiency without sacrificing protection.
Input power factor correction
Minimizes installation costs by enabling the use of smaller generators and cabling.
Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
LCD display
Alpha-Numeric Display which displays system parameters and alarms.
Serial connectivity
Provides management of the UPS via a serial port.
USB connectivity
Provides management of the UPS via a USB port (not available on all models).
Features
Management Software
Allows you to easily monitor your utility power and manage your UPS.
ECO Mode
Operating mode that by-passes unused electrical components in good power conditions to achieve high operating efficiency without sacrificing protection.
Input power factor correction
Minimizes installation costs by enabling the use of smaller generators and cabling.
High efficiency
High efficiency rates that remain stable even at lower operating power levels.
SmartSlot
Customize UPS capabilities with management cards.
Intuitive LCD interface
Provides clear and accurate information in multiple languages with the ability to configure the UPS locally with easy to use navigation keys.
Double conversion on-line topology
Guarantees a consistently high level of power quality. Any disturbances on the distribution waveform are regenerated via the zero transfer time AC to DC then DC to AC conversion process. The battery is only used as a back-up source.
Generator compatible
Ensures clean, uninterrupted power to protected equipment when generator power is used.
Wide input voltage range
Designed for harsh electrical environments to save battery life.
Serviceability
Disconnected battery notification
Warns when a battery is not available to provide backup power.
Audible alarms
Provides notification of changing utility power and UPS power conditions.
Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Predicitive failure notification
Provides early-warning fault analysis ensuring proactive component replacement.
Manageability
Serial connectivity
Provides management of the UPS via a serial port.
SmartSlot
Customize UPS capabilities with management cards.
LCD graphics display
Text and mimic diagrams that display modes of operation, system parameters and alarms.
Network manageable
Provides remote power management of the UPS over the network.
LED Indicators
Provide easy-to-read status of the unit and utility power conditions.
Availability
Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
Battery
Automatic battery test
Yes
Battery recharge time
4 Hour
Battery technology
Sealed Lead Acid (VRLA)
Design
Certification
CE, IEC 62040-1-1, IEC 62040-1-2 REACH
Display type
LCD
Form factor
Rackmount
LED indicators
Y, Yes
Product colour
Black
Rack capacity
2U
Features
Audible alarm modes
Alarm when on battery, Fault, Low battery alarm, Overload alarm
Audible alarm(s)
Yes
Auto-restart
Yes
Crest factor
3:1
ECO mode
Yes
Efficiency
88 %
Emergency Power Off (EPO)
No
Input frequency
40/70 Hz
Input operation voltage (max)
280 V
Input operation voltage (min)
160 V
Input power factor
0.95
Maintenance-free
Yes
Noise level
50 dB
Number of input phases
1
Number of output phases
1
Output frequency
50/60 Hz
Output operation voltage (max)
240 V
Output operation voltage (min)
220 V
Output power
1600 Watt
Output power capacity
2 kVA
Output power factor
0.8
Output voltage regulation
1 %
Output voltage Total Harmonic Distortion (THD)
3 %
Socket circuit breaker
Yes
Surge energy rating
600 J
UPS topology
Double-conversion (Online)
Waveform
Sine
Logistics data
Harmonized System (HS) code
85078000
Operational conditions
Operating altitude
0 - 3000 m
Operating relative humidity (H-H)
0 - 95 %
Operating temperature (T-T)
0 - 40 °C
Storage relative humidity (H-H)
0 - 95 %
Storage temperature (T-T)
-20 - 50 °C
Other features
Nominal input voltage
230 V
Nominal output voltage
230 V
Package dimensions
Depth (package,cm)
59.9 cm
Gross Weight (Package, kg)
23.66 kg
Height (package,cm)
14.2 cm
Width (package,cm)
55.1 cm
Packaging data
Cables included
USB cable
Manual
Yes
Software CD
Yes
Ports & interfaces
AC outlet types
C13 coupler
AC outlets quantity
4 AC outlet(s)
Serial interface
Yes
Serial ports quantity
1
SmartSlot
Yes
USB port
Yes
USB port type
USB Type-B
Product dimensions
Net Weight (Product, kg)
18.2 kg
Product Depth
46.2 cm
Product Height
8.6 cm
Product Width
43.7 cm
Technical details
Sustainability certificates
RoHS
Vendor information
Brand Name
APC
Warranty
1 Year(s)